Breves Notitiae
| Locus Originis: | Guangdong, Sina | Applicatio: | Reticulatio |
| Nomen Marcae: | SOROTEC | Nomen: | UPS 10kva in linea |
| Numerus Modeli: | HP9335C Plus | Tensio egressa: | 208/220/230/240VAC (Ph-N) |
| Phase: | Tres Phases | Regulatio Tensionis AC: | ± 1% |
| Protectio: | Circuitus Brevis | Frequentiae Ambitus (Ambitus Synchronizatus): | 46Hz ~ 54Hz @ systema 50Hz; 56Hz ~ 64Hz @ systema 60Hz |
| Tensio Egressus: | 220VAC/230VAC/240VAC | Frequentiae Ambitus (Modus Batteriae): | 50 Hz ± 0.1 Hz vel 60 Hz ± 0.1 Hz |
| Typus: | In interreti | Ratio Cristae Currentis: | 3:1 maximum |
| Temperatura Operationis: | 0 ~ 40°C (vita pilae decrescet cum > 25°C) | Altitudo Operationis: | <1000m |
| Humiditas Operationis: | <95% et non condensans | Distortio Harmonica: | ≤ 2% @ 100% Onus Lineare; ≤5% @ 100% Onus Non Lineare |
Facultatem Copiae
Involucrum et Traditio
EPO Correctio factoris potentiae activae UPS HP9335C Plus in linea
Proprietates Claves:
1. Eius technologia digitalis DSP (Digital Signal Processor) recentissima, potest magnopere augere efficaciam productorum et firmitatem systematis, et praebere integrationem compactam cum densitate potentiae altiore;
2. Factor potentiae egressus usque ad 0.8 - applicabilis inclinationi evolutionis oneris futuri, et maiorem capacitatem oneris praebet;
3. Factor potentiae totalis usque ad 90% potest iacturam potentiae UPS minuere et sumptum usus pro usore servare;
4. Interclusio Potestatis in Casu Necessitatis (EPO): Systema UPS in casu cuiuslibet necessitatis statim intercludi potest;
5. Obsequendo requisitis EMC normae IEC61000-4, praebe instrumento tuo ambitum electricum mundum.
6. Technologia correctionis factoris potentiae activae (PFC) permittit factorem potentiae ingressae ad 1 appropinquare, immunitatem in reti utilitatis vehementer minuens;
7. Excellens frequentiae amplitudo ingressus UPS aptum reddit variis machinis potentiae alimentorum, exempli gratia generatori;
8. Instrumentum Parallelum: functionem extensionis parallelae et redundantiae efficit, maiorem flexibilitatem et salutem pro consilio alimentationis electricae usoris offert;
9. Designatio Compacta, Sonitus Minor;
Descriptiones Productorum UPS 15Kva
| MODELLUM | HP9335C Plus 10-30KVA | ||||||||
| Decem milia | 10K-XL | Quindecim milia | 15K-XL | Viginti milia | 20K-XL | Triginta milia | 30K-XL | ||
| CAPACITAS | 10KVA / 9KW | 15KVA / 13.5KW | 20KVA / 18KW | 30KVA / 27KW | |||||
| PHASIS | Triphasis cum Neutro | ||||||||
| INPUT | |||||||||
| Ambitus Tensionis | Damnum Lineae Humile | 110 VAC (Ph-N) ± 3% ad onus 50%; 176 VAC (Ph-N) ± 3% ad onus 100% | |||||||
| Reditus Humilis Lineae | Tensio amissa lineae humilis +10V | ||||||||
| Alta Iactura Lineae | 300 VAC (Ph-N) ± 3% | ||||||||
| Reditus in Linea Alta | Alta Tensio Amissa Lineae - 10V | ||||||||
| Phase | Triphasis cum terra | ||||||||
| Factor Potentiae | ≥ 0.99 ad onus 100% | ||||||||
| PRODUCTIO | |||||||||
| Tensio egressa | 208/220/230/240VAC (Ph-N) | ||||||||
| Regulatio Tensionis AC | ± 1% | ||||||||
| Frequentiae Ambitus (Ambitus Synchronizatus) | 46Hz ~ 54Hz @ systema 50Hz; 56Hz ~ 64Hz @ systema 60Hz | ||||||||
| Frequentiae Ambitus (Modus Batteriae) | 50 Hz ± 0.1 Hz vel 60 Hz ± 0.1 Hz | ||||||||
| Onus nimium | Modus AC | 100%~110%: 10 min; 110%~130%: 1 min; >130%: 1 secund. | |||||||
| Modus pilae | 100%~110%: 30 secundis; 110%~130%: 10 secundis; >130%: 1 secundis. | ||||||||
| Ratio Cristae Currentis | 3:1 maximum | ||||||||
| Distortio Harmonica | ≤ 2% @ 100% Onus Lineare; ≤ 5% @ 100% Onus Non Lineare | ||||||||
| Tempus Translationis | Linea←→Alimentum | 0 ms | |||||||
| Inverte ←→Praetergredi | 0 ms (Cum claustra phasis deficit, interruptio <4ms ab invertere ad bypass fit) | ||||||||
| Linea←→ECO | <10 ms | ||||||||
| EFFICIENTIA | |||||||||
| Modus AC | > 89% | > 89% | > 89% | > 90% | |||||
| Modus Batteriae | > 86% | > 88% | > 87% | > 89% | |||||
| PILA | |||||||||
| Modellum Standardum | Typus | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | ||||
| Numeri | 20 (18-20 adaptabile) | 2 x 20 (18-20 adaptabile) | 2 x 20 (18-20 adaptabile) | 3 x 20 (18-20 adaptabile) | |||||
| Tempus Recargandi | Horae novem ad capacitatem 90% recuperandam | ||||||||
| Currens Implendi | 1.0 A ± 10% (max.) | 2.0 A ± 10% (max.) | 2.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | |||||
| Tensio Implendi | 273 VDC ± 1% | ||||||||
| Modelus Longi Cursus | Typus | Pro applicationibus | |||||||
| Numeri | XVIII-XX | ||||||||
| Currens Implendi | 4.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | 12.0 A ± 10% (max.) | |||||
| Tensio Implendi | 273 VDC ± 1% | ||||||||
| PHYSICUS | |||||||||
| Modellum Standardum | Dimensiones, P x L x A (mm) | 832 X 250 X 894 | 832 X250X1275 | ||||||
| Modelus Longi Cursus | Dimensiones, P x L x A (mm) | 609 X 250 X 768 | 832 X 250 X 828 | ||||||
| AMBIENS | |||||||||
| Temperatura Operationis | 0 ~ 40°C (vita pilae decrescet cum > 25°C) | ||||||||
| Humiditas Operationis | <95% et non condensans | ||||||||
| Altitudo Operationis | <1000m | ||||||||
| Gradus Sonitus Acousticus | Minus quam 58dB @ 1 Metrum | Minus quam 60dB @ 1 Metrum | |||||||
| ADMINISTRATIO | |||||||||
| RS-232 / USB callidus | Sustinet systemata Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, et MAC | ||||||||
| USB | Administratio potentiae ex administratore SNMP et navigatro interretiali | ||||||||